TMDL750
Electromechanical Actuator 750 Pound Capacity |
|

|
LSPD 2775 -
12 VDC with limit switches |
| LSPD
2774 - 24 VDC with limit switches |
| PSPD 2775
- 12 VDC with limit switches and potentiometer |
| PSPD 2774
- 24 VDC with limit switches and potentiometer
|
| Stroke Lengths |
4, 8, 12, and 18 inch, 100, 200, 300,
450 mm |
| Motor Protection |
Automatic reset thermal overload in
motor |
| Limit Switches |
Independent, adjustable |
| Temperature Range |
-20°F. to 104°F
Ambient -29°C to 40°C |
| Drive |
ACME Screw |
| Housing |
Aluminum |
| Standard Mounting |
Double Clevis |
| Restraining Torque |
125 in lbs, 14.13 N-m |
| Feedback |
Potentiometer |
| 12 VDC motor is
totally enclosed, permanent magnet type. Magnets act as a
secondary brake for added safety. This type of motor is smaller, cooler
running, more efficient and has higher duty cycles than series-wound
motors. Lower current draw provides for longer battery life.
The motor is also equipped with a thermal overload device that opens and
resets automatically. The rotation is reversible by reversing the
two color coded leads. Torque is the same in either
direction. |

|
24 VDC motor is
totally enclosed, permanent magnet type. This type of motor is
smaller, cooler running, more efficient and has higher duty cycles than
series wound motor. Lower current draw provides for longer battery
life. Rotation is reversible by reversing the two color coded
leads. Torque is the same in either direction. The motor is
also equipped with a thermal overload device that opens and resets
automatically. |
|
Controls
are also available for these actuator models as follows: |
- Control Package PDC -1R = PSPD 2775 &
LSPD 2775
- Control Package
PDC-2R = PSPD 2774 & LSPD 2774
|
|
Additional
Notes |
- Some actuator surface temperatures may reach
230°F at or near maximum allowable duty cycle.
- The thermal overload resets in 10
minutes
- All ratings are normal and based on
the actuator being broken in for approximately 2500 inches of travel
- Two DPST-Normally Open relays
(supplied by customer) are required to operate the actuator if the
Duff-Norton Controls are not present.
|
|
Performance
Characteristics |
|