TMAL1000-HD
Electromechanical Actuator 1000 Pound Capacity

SPA 3410 - 115 VAC (60Hz) with Limit Switches
SPA 4410 - 220 VAC (50Hz) with Limit Switches
PSPA 3410 - 115 VAC (60Hz) with Limit Switches and Potentiometer
PSPA 4410 - 220 VAC (50Hz) with Limit Switches and Potentiometer

Additional Information

Stroke Lengths 3, 6, 12, 18, and 24 inch, 75, 150, 300, 450, 610 mm
Motor Protection Automatic reset thermal overload in motor
Temperature Range -20°F. to 104°F Ambient -29°C to 40°C
Drive Ball Screw
Housing Zinc Aluminum die casting
Standard Mounting Double Clevis
Limit Switches Independent, externally adjustable
Restraining Torque 100 in lbs, 11.30 N-m
Brake Electric
Feedback Potentiometer
Cable Entrance 1/2" NPT and 3/4" NPT

115 VAC motor is an enclosed, permanent split capacitor induction type.  The motor is equipped with a thermal overload device that opens and resets automatically.  Standard motor requires 28-33 mfd capacitor supplies by either the customer, or Duff-Norton at extra cost, for loads up to 250 pounds.  High speed motors require a 64-72 mfd capacitor, also available from Duff-Norton.  A capacitor box is available on AC models only. 

220 VAC motor is totally enclosed, permanent split capacitor induction type.  Load/no-load speeds are approximately equal.  Equipped with thermal overload device that opens and resets automatically.  Standard motor requires 10 mfd 440VAC, 60/50Hz metalized polypropylene capacitor supplied by Duff-Norton. 

Controls are also available for these actuator models as follows:

  • Control Package PAC -1CR = PSPA 3410
  • Control Package PAC-2CR = PSPA 4410

Additional Notes

  • Some actuator surface temperatures may reach 230°F at or near maximum allowable duty cycle.
  • The thermal overload resets in 10 minutes.
  • All ratings are normal and based on the actuator being broken in for approximately 2500 inches of travel.
  • 2 DPST-NO relays (supplied by customer) are required to operate the actuator if the Duff-Norton Controls are not used.